You are currently exploring our in-stock options for part number 138C185H02 with the NSN 5950011482295. This product is listed with the description “Transf Pul” and is manufactured by Technetics Inces Inc. If you are looking to purchase this part, we encourage you to complete and submit the RFQ form below with as much information as you can provide, such as your desired quantity, budget, shipping time frame, and more. Within 15 minutes of receiving and reviewing your submission, one of our experts will reach out with a quote that is tailored to your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We supply all relevant information alongside the listings on our website, that way you know you are always getting the exact item you require. For example, part number 138C185H02 is listed alongside the NSN 5950-01-148-2295 and belongs to the FSC 5950 Coils and Transformers. Additionally, it is also under the CAGE Code 58701, which is assigned to Technetics Inces Inc. At Aerospace Procurement, you can trust that each product in our inventory is up to industry standards, as we are committed to various quality assurance practices. For example, we uphold a strict NO CHINA SOURCING pledge to ensure that each part is shipped out alongside its manufacturer trace documentation and qualifying certifications. These practices and more allow us to operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. Get in contact with us today to see how we can make the procurement process for part number 138C185H02 seamless.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-148-2295 Item PartTypeName: TRANSF PUL | 5950 | 011482295 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
138C185H02 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | TRANSFORMER,PULSE |
FEAT | SPECIAL FEATURES | PULSE TRANSFORMER IS DESIGNED FOR INTERMEDIATE PULSE LEVELS OF 100 TO 2,000 VOLTS AND WITH DC WINDING INSULATIONS SUITABLE FOR COUPLING BETWEEN CIRCUITS OF HIGH POTENTIAL DIFFERENCE |
SPCL | SPECIAL TEST FEATURES | TURNS RATIO: 1:1; PRIMARY SINE WAVE OCL MH MINIMUM: 0.6; PRIMARY ET-CONSTANT: 1000 (V MINIMUM); RISE TIME (N5 MAX): 20; PRI/SEC CW/H (PF MAXIMUM): 65; PRI/SEC LEAKAGE INDUCTANCE (AAH MAXIMUM): 3.0; PRIMARY DCR (OHMS MAXIMUM): 0.15; SECONDAR |
SUPP | SUPPLEMENTARY FEATURES | RATINGS: PEAK POWER: 25KW; AVERAGE POWER: 25 WATTS; PEAK PULSE VOLTAGE: 2KV; DC ISOLATION PRIMARY TO SECONDARY SHALL BE 5KV MINIMUM; PARTS SHALL WITHSTAND THE FOLLOWING HIGH POTENTIAL TEST WITHOUT ELECTRICAL DAMAGE,ARCING OR FLASHOVER: SEC |
TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | PARTS SHALL MEET THE REQUIREMENTS OF MIL-T-21038,GRADE 5,CLASS S,LIFE X UNLESS OTHERWISE SPECIFIED ON DRAWING |