You are currently exploring our in-stock options for part number APGN1-1-51-502 with the NSN 5925014528209. This product is listed with the description “Circuitbreaker” and is manufactured by Sager Electrical Supply Company Inc. If you are looking to purchase this part, we encourage you to complete and submit the RFQ form below with as much information as you can provide, such as your desired quantity, budget, shipping time frame, and more. Within 15 minutes of receiving and reviewing your submission, one of our experts will reach out with a quote that is tailored to your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We supply all relevant information alongside the listings on our website, that way you know you are always getting the exact item you require. For example, part number APGN1-1-51-502 is listed alongside the NSN 5925-01-452-8209 and belongs to the FSC 5925 Circuit Breakers. Additionally, it is also under the CAGE Code 7A884, which is assigned to Sager Electrical Supply Company Inc. At Aerospace Procurement, you can trust that each product in our inventory is up to industry standards, as we are committed to various quality assurance practices. For example, we uphold a strict NO CHINA SOURCING pledge to ensure that each part is shipped out alongside its manufacturer trace documentation and qualifying certifications. These practices and more allow us to operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. Get in contact with us today to see how we can make the procurement process for part number APGN1-1-51-502 seamless.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-452-8209 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014528209 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
APGN-1-1-51-502 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
BBRJ | Special Handling Feature | MAGNETIC |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEFP | Nonturn Device Radius | 0.656 INCHES NOMINAL |
ABXD | Bushing Length | 0.625 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 65.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 DC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AEFN | Nonturn Device Location | AT 3 OCLOCK AND AT 9 OCLOCK |
AEFQ | Nonturn Device Length | 0.130 INCHES NOMINAL |
AKPX | Pole Quantity | 2 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 1.500 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT POLE TWO |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 2.200 INCHES MAXIMUM |
AEFS | Nonturn Device Diameter | 0.156 INCHES NOMINAL |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
CQJX | Nominal Thread Size | 0.500 INCHES |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.530 INCHES NOMINAL |
THSD | Thread Series Designator | UN |
TTQY | Terminal Type And Quantity | 4 TAB, SOLDER LUG |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF AND FUNGUS PROOF |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.