You are currently exploring our in-stock options for part number 19333 with the NSN 5950013313167. This product is listed with the description “Transformer Power” and is manufactured by Robert M Hadley Company Inc. If you are looking to purchase this part, we encourage you to complete and submit the RFQ form below with as much information as you can provide, such as your desired quantity, budget, shipping time frame, and more. Within 15 minutes of receiving and reviewing your submission, one of our experts will reach out with a quote that is tailored to your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We supply all relevant information alongside the listings on our website, that way you know you are always getting the exact item you require. For example, part number 19333 is listed alongside the NSN 5950-01-331-3167 and belongs to the FSC 5950 Coils and Transformers. Additionally, it is also under the CAGE Code 72964, which is assigned to Robert M Hadley Company Inc. At Aerospace Procurement, you can trust that each product in our inventory is up to industry standards, as we are committed to various quality assurance practices. For example, we uphold a strict NO CHINA SOURCING pledge to ensure that each part is shipped out alongside its manufacturer trace documentation and qualifying certifications. These practices and more allow us to operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. Get in contact with us today to see how we can make the procurement process for part number 19333 seamless.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-331-3167 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013313167 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
19333 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 4.700 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 45.0 HERTZ MINIMUM SINGLE COMPONENT AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
CRMJ | WINDING POWER RATING | 508.32 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.18 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 9.200 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.885 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 7.915 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 6.185 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 6.215 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ADAT | BODY WIDTH | 7.500 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.312 INCHES SINGLE GROUP |
TEST | TEST DATA DOCUMENT | 13973-841330 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |
CRBZ | WINDING OPERATING CURRENT | 375.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 24.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 78.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote