You are currently exploring our in-stock options for part number 43063 with the NSN 5950004262675. This product is listed with the description “Transformer Power” and is manufactured by Freed Transformer Company. If you are looking to purchase this part, we encourage you to complete and submit the RFQ form below with as much information as you can provide, such as your desired quantity, budget, shipping time frame, and more. Within 15 minutes of receiving and reviewing your submission, one of our experts will reach out with a quote that is tailored to your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We supply all relevant information alongside the listings on our website, that way you know you are always getting the exact item you require. For example, part number 43063 is listed alongside the NSN 5950-00-426-2675 and belongs to the FSC 5950 Coils and Transformers. Additionally, it is also under the CAGE Code 73386, which is assigned to Freed Transformer Company. At Aerospace Procurement, you can trust that each product in our inventory is up to industry standards, as we are committed to various quality assurance practices. For example, we uphold a strict NO CHINA SOURCING pledge to ensure that each part is shipped out alongside its manufacturer trace documentation and qualifying certifications. These practices and more allow us to operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. Get in contact with us today to see how we can make the procurement process for part number 43063 seamless.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-426-2675 Item PartTypeName: TRANSFORMER,POWER | 5950 | 004262675 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
388201 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 15.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 18.5 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY330.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY6.30 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY6.30 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 330.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY330.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 35.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY35.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 15 TURRET |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.063 INCHES NOMINAL3.063 INCHES NOMINAL3.063 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.625 INCHES NOMINAL2.625 INCHES NOMINAL2.625 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.250 INCHES NOMINAL4.250 INCHES NOMINAL4.250 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 50.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED WITH OILHERMETICALLY SEALED WITH OILHERMETICALLY SEALED WITH OIL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |