We at ASAP Semiconductor appreciate your vested interest in the NSN 5945-00-238-3068 inventory we offer here on Aerospace Procurement. Below, we have presented a variety of information pertaining to NSN 5945-00-238-3068 supplies, as well as part numbers like 17977301, 7024AA, and others. Take your time perusing resources, and if you find any items that match your requirements, we encourage you to request a quote. Our online Request for Quote (RFQ) forms simplify the process of obtaining pricing and procurement details, enabling you to submit information like your budget and expected fulfillment timeline to receive tailored responses from our staff within 15 minutes of our review. You can also give us a call or email using the information at the bottom of this webpage, as we would be happy to hear about your needs and assist you that way.
When you order NSN 5945-00-238-3068 parts from us, you can rest assured that only the best items will reach your hands. Every component on our website can be traced back to a manufacturer that we trust, and a myriad of listings are inspected and tested for fit, form, and function as necessary. More than that, we adhere to a strict NO CHINA SOURCING pledge, which means that all products are shipped out alongside any relevant manufacturer trace documentation or qualifying certifications to verify their origin and authenticity. Taking this into account, get in touch with a team member whenever you are ready to get started on procurement!
Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 00-238-3068 (002383068) |
NCB Code | USA (00) |
Manufacturer | Control Data Systems Inc, Syntegra Usa Inc, Tyco Electronics Agastat Relays |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 3.320 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 5.820 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.250 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SECOND MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 62.798 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.10 SECONDS MINIMUM ADJUSTABLE RELEASE TIME AND 1.00 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
CWJB | ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 SCREW ALL FUNCTIONS |
Relevant Components for NSN - 5945-00-238-3068, 5945002383068 | ||||
5905-00-763-7181 (5905007637181) | 5910-01-268-7617 (5910012687617) | 5999-01-498-2622 (5999014982622) | 5998-01-263-5256 (5998012635256) | |
5995-01-439-1800 (5995014391800) | 5940-01-044-5977 (5940010445977) | 5999-01-323-1386 (5999013231386) | 5998-00-832-5847 (5998008325847) | |
5955-01-295-2815 (5955012952815) | 5940-00-413-1421 (5940004131421) | 5950-01-134-0674 (5950011340674) | 5930-00-908-2989 (5930009082989) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.