We at ASAP Semiconductor appreciate your vested interest in the NSN 5925-01-181-7283 inventory we offer here on Aerospace Procurement. Below, we have presented a variety of information pertaining to NSN 5925-01-181-7283 supplies, as well as part numbers like TEB132060WL, W-C-375 12, WC375 12-010, and others. Take your time perusing resources, and if you find any items that match your requirements, we encourage you to request a quote. Our online Request for Quote (RFQ) forms simplify the process of obtaining pricing and procurement details, enabling you to submit information like your budget and expected fulfillment timeline to receive tailored responses from our staff within 15 minutes of our review. You can also give us a call or email using the information at the bottom of this webpage, as we would be happy to hear about your needs and assist you that way.
When you order NSN 5925-01-181-7283 parts from us, you can rest assured that only the best items will reach your hands. Every component on our website can be traced back to a manufacturer that we trust, and a myriad of listings are inspected and tested for fit, form, and function as necessary. More than that, we adhere to a strict NO CHINA SOURCING pledge, which means that all products are shipped out alongside any relevant manufacturer trace documentation or qualifying certifications to verify their origin and authenticity. Taking this into account, get in touch with a team member whenever you are ready to get started on procurement!
Item Name | Circuit Breaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-181-7283 (011817283) |
NCB Code | USA (01) |
Manufacturer | Porta Kamp Construction Inc, Federal Specifications |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
TEB132060WL | porta kamp construction inc | circuit breaker | 23644 | RFQ |
W-C-375 12 | federal specifications | circuit breaker | 81348 | RFQ |
WC375 12-010 | federal specifications | circuit breaker | 81348 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 6.310 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.105 INCHES MINIMUM AND 4.125 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.380 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.250 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.380 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.880 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.380 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.250 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE AND 2 UNTHREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 60.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TEST | TEST DATA DOCUMENT | 81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING G |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
ZZZK | SPECIFICATION/STANDARD DATA | 81348-W-C-375/12 GOVERNMENT SPECIFICATION |
Relevant Components for NSN - 5925-01-181-7283, 5925011817283 | ||||
5975-01-508-4990 (5975015084990) | 5950-01-023-3083 (5950010233083) | 5915-01-253-2791 (5915012532791) | 5998-01-091-0401 (5998010910401) | |
5930-01-293-6417 (5930012936417) | 5985-01-082-9620 (5985010829620) | 5962-01-500-6232 (5962015006232) | 5950-00-225-6775 (5950002256775) | |
5905-01-411-2830 (5905014112830) | 5935-00-465-4296 (5935004654296) | 5905-01-105-8818 (5905011058818) | 5940-01-297-3868 (5940012973868) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote